01 - measurements of geometric quantities | Calipers, depth gauges | from 0 to 500 mm, A - ± from 0.02 to ± 0.2 mm | II-IV quarter | on request |
| Laser rangefinder | from 0.05 to 100 m, A - 1 from 1 to 3 mm | II-IV quarter | on request |
| Micrometers | from 0 to 200 mm, A “ from ±0.004 to ± 0.0085 mm | II-IV quarter | on request |
| Anti-angle meters | from 0 to 360°, A = ±2', ±5', ± 10' | II-IV quarter | on request |
| Theodolites and levels | from 0° to 90°, RMS = from ± 1 "to ±60 " | II-IV quarter | on request |
02 - mass measurements | Scales | from 1 g to 20 kg, A = ± 5 mg to ± 10 kg | II-IV quarter | on request |
03 - force and hardness measurements | Torque wrenches | from 0.5 to 1100 Nm from 3 to 5% | II-IV quarter | on request |
| Hardness tester | O1 8 to 450 11B, O1 8 to 2000, HV. C scale from 20 to 70 HRC. A scale from 70 to 93 HRA. B scale from 25 to 100 HRB. N scale from 70 to 94 HRN15. From 40 to 86IIRN30, from 20 to 78 HRN45. T scale from 62 to 93 HRT15, from 15 to 8211RT30. From 10 to 72IIRT45OT23 to 102 HSD. 6 - from ± 3% to ± 5%. A = from ± 1.0 units of solids to ± 3 d.sols | II-IV quarter | on request |
04 - pressure measurements | Barometer | from 0.5 to 110 kPa, A = from ± 0.11 to 0.33 Pa | II-IV quarter | on request |
| Blood pressure monitors, tonometers | from 0 to 39.99 kPa. From 0 to 300 mmHg, A = ± 0.39 kPa, A = from ± 0.5 to ± 4 mmHg | II-IV quarter | on request |
| Manometers indicating, digital, self-recording, electronic, pressure and vacuum gauges, vacuum meters | from minus 0.1 to 110 MPa 8 = from ± 0.4% to ± 4% | II-IV quarter | on request |
06 - motion parameter measurements | Tachographs | from 4 to 250 km/h, A = ±3 km/h | II-IV quarter | on request |
| Anemometers, pressure tubes, Pitot | | II-IV quarter | on request |
07 - liquid and gas flow and quantity measurements | Metal standard measuring cylinders | from 2 to 50 dm~3, 8 = ± 0.02% | II-IV quarter | on request |
| Gas meter | from 0 to 65 m3/h, 8 = from ± 0.5% to ± 2.0% | II-IV quarter | on request |
| Dispensers pipette | 0.2 to 50,000 µl, 8 ~ ± 0.1% to ± 8.0% | II-IV quarter | on request |
| Liquid meters | 0 to 150 m3/h, 8 = ± 0.5% to 2.5% | II-IV quarter | on request |
08 - density and viscosity measurements | Glass hydrometers | 650 to 1840 kg/m3, A = ± 0.1 to ± 20 kg/m3 | II-IV quarter | on request |
| Viscometers | 0.6 to 30,000 mmg/s, 8 = ± 0.2% to ± 2.5% | II-IV quarter | on request |
09 - physicochemical measurements | Thermohygrometers | from 1 to 98%, U = ± 0.4% at k = 2 and P = 95%, A = ± from 1 to ± 5% | II-IV quarter | on request |
| Ion meter, pH meter | EMF from minus 2000 to 4000 mV. From minus 3000 to 30000 mV. From minus 20 to 20 pH, from minus 20.00 to 20.00 рХ. A = ± from 0.01 to 0.6 pH units, A = from ± 0.3 to ± 5 mV | II-IV quarter | on request |
| Dew point analyzers | from minus 70 °C to 20 °C, A = ± from 2 to 5 °C | II-IV quarter | on request |
10 - thermophysical and temperature measurements | Thermocouples | NSH (type K) from minus 40 °C to 1000 °C. From 4 to 20 mA. NSH (column 50 M, 100M). From minus 50 °C to 180 °C. From 0 to 5 mA. From 4 to 20 mA. NSH (column 1 OOP, PH 00), from minus 50 °C to 500 °C. From 0 to 20 mA, Y = from ±0.25% to ±1.0% | II-IV quarter | on request |
| Laboratory thermometers | from minus 80 °C to 200 °C 8-dov = ±from 0.15 °C to 5.0 °C, A = ±(0.1% + 0.7) °C | II-IV quarter | on request request |
| Pyrometers, thermal imagers | from minus 50 °C to 1100 °C, A = ±0.7 °C | II-IV quarter | on request |
11 - optical and physical measurements | Photoelectric colorimeter concentration colorimeter | from 315 to 9802 nm. From 1 %T to 100 %T, A = from ±0.5 % 'G to ±2.5 % T | II-IV quarter | on request |
| Luxometer | from 1.00 to 20,000 lx, 3 = from ±2 % to ±15% | II-IV quarter | on request |
13 - measurements of electrical quantities | Megohmmeter | from 0.1 Ohm to 1 TΩ. From 100 to 10,000 V, 8 = from ±1 % up to 20% | II-IV quarter | on request |
| Measures and resistance boxes | from 0.001 Ohm to 100 MOhm, cl.t from 0.02 to 2 | II-IV quarter | on request |
| Ammeter | from 0 to 10 A | II-IV quarter | on request |
| Transformer current ammeter | cl.t from 0.1 to 4 from 0 to 5000 A. From minus 30 degrees, up to 30 degrees | II-IV quarter | on request |
| Universal voltmeters and digital multimeters | from 0 to 1000 V. From 0 to 10 A. From 0 to 1 K >m. From 0 to 60 MHz. 3 - from 0.1 to 5% | II-IV quarter | on request |
| Electric energy meters | U = from 40 to 400 V. 1 = from 0.05 to 10 A. P - from 0.011HUH W to 1.5IH1.2UH W. Q - from 0.05IHUH var to 1.5IH1.2UH var. F = from 44.4999 to 51 Hz. Ф = from minus 180°. cl.t 0.2-0.5 | II-IV quarter | on request |
| Wattmeters | from 10“6 A to 10 A. From 10-6 V to 1000 V. From 40 Hz to 65 Hz. From 0 to 1200 kW | II-IV quarter | on request |
| Panel frequency meter | from 10 to 100 Hz. From 0 to 380 V | II-IV quarter | on request |
15 - time and frequency measurements | Oscilloscope | from 0.1 Hz to 50 MHz. From 0 to 50 V | | |
8 = from ± 0.1 to ± 15 % | II-IV quarter | on request | | |
16 - radio engineering measurements | Low-frequency signal generators | from 0 to 100 MHz 8 _ ± from 3 to 6 % | II-IV quarter | on request |